Navigation: Installing EventSentry > Updating to a new version > Updating from version 2.60 |
This chapter contains very important information for users updating to version 2.7x from earlier versions of EventSentry. Read this chapter carefully to avoid losing parts of your configuration.
Local Filters With the introduction of filter packages, the previously introduced Local Filters feature has become obsolete and will not be supported anymore. While local filters will be migrated to a "Local Filters Package" on the computer where you run the EventSentry setup, they will be lost on remote computers that are updated with the remote update feature.
If you need to retain the local filters that you created on remote computer then you will have follow the steps below:
Global Filters With the introduction of filter packages, the previously introduced Global Filters feature will not be available anymore, instead you can create global packages that will be processed on all computers. Global filters will be automatically migrated to a Migrated Global Filters package when updating to version 2.70.
Packages Starting with version 2.70, filters are not organized through groups, global and local containers anymore. Instead, filters are organized into filter packages which are then assigned to either groups or computers. Filter packages can also be made global so that they apply to all computers, regardless of group membership.
Your configuration will of course be preserved, and all filters that previously belonged to a group will be automatically migrated to a package. For example, all filters from the SERVERS group will be migrated to Migrated filters from SERVERS. Health and tracking packages are now also organized using packages, and will migrated in a similar fashion.
We recommend that you review your configuration after the migration carefully and make adjustments as necessary. For example, you will almost always be able to consolidate your health packages into one or two packages.
Filter package order is not relevant for package/filter processing. Exclude filters will always be processed before include filters, regardless of their package order.
Database Since new tables were added to the database it is also necessary to update the database. If you are using Microsoft SQL Server, then you the database will be automatically updated during the installation, make sure that you select the database feature and provide login information.
If you are using MySQL, Oracle or Access then you will need to update the database using the Database Setup Wizard. Running the Database Setup Wizard after the installation has been updated will ensure that all necessary tables exist.